Page 26 - Gazette - November 2023
P. 26

DOSATRON


                                                                 Keep the suction hose foot filter in
           DEPENDABILITY                                         place

                                                                 WHY? The filter is your safety net to prevent
           Dosatron units are used to inject a range of products for
                                                                 particulates and debris from getting into the fluid
           different applications. Fertilizers, acids for pH management,   path and causing premature wear of the injector.
           fungicides and insecticides for root zone application,
           beneficial nematodes, and sanitation products can all be   HOW? Simply read the instruction manual and
           mixed with a Dosatron.                                ensure the strainer/filter is installed properly.
                                                                 EXCEPTION: The foot filter is often removed
                                                                 when applying nematodes as a safeguard for
                                                                 survivability and to prevent clogging.

                                                                 Choose the right seals
                                                                 for the job
                                                                 WHY? Products with high pH and products
                                                                 containing peroxyacetic acid (PAA) can cause
                                                                 standard seals to fail.
                                                                 HOW? Use Viton (VF) seals for products with acid
                                                                 to neutral pH (pH 1-7), including most fertilizers,
                                                                 pesticides, supplements, and surfactants.
                                                                 Use Aflas (AF) seals for high pH products (pH
                                                                 7-14), including calcium carbonate, potassium
                                                                 carbonate, and liquid lime. Use Kalrez (K) seals for
                                                                 PAA products, such as ZeroTol 2.0 and SaniDate
                                                                 products.

                                                                 Perform maintenance every 6-9 months
                                                                 (Mini) and every 9-12 months (Injection
                                                                 Seal)

                                                                 WHY? When seals and O-rings wear out, you lose
                                                                 accuracy. Wear is normal, so get ahead of it with
                                                                 simple maintenance.
                                                                 HOW? Keep Dosatron Mini Maintenance Kits
                                                                 and Injection Seal Kits on hand. Kits include
                                                                 replacement seals, springs, and O-rings along
                                                                 with instructions and proper lubricant for your
                                                                 Dosatron.











        26  |  GRIFFIN GAZETTE 2023